G60-U01-AKH-F8L-H67-M8L-P6D-U6D-W6C (GE Multilin Generator Protection Relay)

G60-U01-AKH-F8L-H67-M8L-P6D-U6D-W6C (GE Multilin Generator Protection Relay)

Model Decoding (UR Series Coding Rules)

G60: Product series, integrated generator protection system

U01: CPU Type U, Software Option 01 (Basic Protection + Advanced Communication)

AKH: Mounting / Display / Power Supply → A = 19-inch vertical mounting, K = Enhanced panel, H = 125/250 VDC

F8L: CT/VT Module → 4 CT + 4 VT with enhanced diagnosis

H67: Hard Contact Output → 6 normally open contacts + 7 programmable contacts

M8L: Additional CT Module → 8 CT channels with enhanced diagnosis

P6D: Communication Port 1 → 6 ports, Dual Ethernet + RS485, compliant with IEC 61850

U6D: Communication Port 2 → 6 ports, Dual Ethernet + RS485, redundant design

W6C: Expansion Module → 6 control outputs with monitoring function

Description

Basic Parameters

Brand / Series: GE Multilin (UR Series)
Protected Objects: Large and medium-sized synchronous generators (steam turbine / gas turbine / water turbine)
Processor: 32-bit RISC, high-performance real-time processing
Sampling Accuracy: 64 samples per cycle, 0.5 ms event resolution
Power Supply: 125/250 VDC (Type H), wide-range redundant power supply
Dimensions: 19-inch standard rack (vertical mounting)
Protection & Certifications: IP20, CE, UL, RoHS, IEC 61850

Core Functions

Stator differential protection, 100% stator earth fault protection (requires GPM-S module), rotor earth fault protection (requires GPM-F module)

Loss of excitation / overexcitation, reverse power, negative sequence, overcurrent / overvoltage, frequency deviation, out-of-step blocking

Communication & Redundancy (GE Vernova)

3 independent Ethernet ports (supports IEC 61850, Modbus TCP, PRP redundancy)
RS485 (Modbus RTU), RS232 (for local commissioning)

Monitoring & Waveform Recording

Electrical Measurement: Current, Voltage, Active Power, Reactive Power, Frequency, Harmonics
Event Logging: 1024 time-stamped events
Fault Recording: Up to 64 fault records, 16 synchronous channels

High Availability Design

Built-in hardware self-diagnosis, redundant key circuits, hot standby switchover
CyberSentry cybersecurity (NERC CIP compliant)

Application Scenarios

Power Plants: Main protection for generators in thermal power, hydropower, wind power and photovoltaic power stations
Industrial Power Generation: Protection for generators and generator-transformer units in captive power plants of metallurgy, chemical and oil & gas industries
Substations: Protection for synchronous condensers and shunt reactors in large substations
High-end Applications: Smart power stations requiring IEC 61850, process bus and PRP redundancy (GE Vernova)