Description
Channel & Wiring Configuration
-
8 differential signal input channels, matched for SCXI high-speed analog modules
-
Independent dual DIP switches per channel for AC/DC coupling switching
-
Configurable floating/ground-referenced input via internal bias resistors
-
22 gold-plated screw terminals for secure stranded/solid wire connection
Coupling & Filter Parameters
-
DC Coupling: Direct signal transmission, 200 kHz full signal bandwidth
-
AC Coupling: Single-pole high-pass filter, -3dB cutoff at 0.7 Hz
-
Internal bias resistor: 100 kΩ for floating sensor grounding
-
Input parasitic capacitance: 22 pF per differential channel
Key Electrical Specifications
-
Maximum continuous input voltage: ±60 VDC/Vrms channel-to-chassis
-
Transient overvoltage withstand: 1000 V peak surge
-
Input impedance: 1 MΩ parallel with 22 pF
-
Channel crosstalk: <-90 dB at 1 kHz
-
Insulation resistance: >1 GΩ between channels and shielding shell
-
Power consumption: Passive device, no external power required
Mechanical & Environmental Specifications
-
Mounting: Direct front mounting for standard 96-pin SCXI modules
-
Shell: EMI-shielded aluminum alloy anti-interference housing
-
Dimension: 172×42×32 mm, half-height SCXI front accessory
-
Operating temperature: -20℃ ~ +70℃, humidity: 10%–90% non-condensing
Software Compatibility
-
Drivers: No dedicated driver, compatible with NI-DAQmx and Traditional NI-DAQ
-
Supported software: LabVIEW, LabWindows/CVI, Python DAQmx, C#
-
Compatible host: SCXI-1600, PCI/PXI DAQ acquisition cards
Pros & Limitations
-
Pros: Passive no-power design, independent channel coupling control, built-in bias grounding, integrated shielding, excellent low-frequency DC interference suppression
-
Limitations: Only compatible with SCXI-1140 series modules, no built-in signal amplification, not applicable for thermocouple low-level DC signals








Reviews
There are no reviews yet.