Description
Port & Physical Interface Configuration
-
Two hardware variants: PXI-8423/2 (2-port DB-9 male) / PXI-8423/4 (4-port 10P10C modular jack)
-
Front panel integrated signal activity LED indicators for each serial channel
-
Standard single-width 3U PXI form factor, occupies only one independent PXI peripheral slot
-
Dimension: 100 × 160 mm, compatible with all standard 3U PXI chassis
-
Accessory matching: 10P10C to DB-9 breakout cable required for 4-port variant field wiring
Serial Communication Core Parameters
-
Supported protocols: Half-duplex/full-duplex RS-485, full-duplex RS-422
-
Max baud rate: 460.8 kbps, compatible with all standard industrial baud rate gears
-
Hardware buffer: 64-byte independent transmit/receive FIFO per channel
-
Max cable length: 1.2 km under low EMI environment; limited to 30 m for EMC surge compliance
-
Node capacity: Up to 31 slave nodes on a single RS-485 bus segment
Galvanic Isolation & Protection Ratings
-
Port-to-host isolation withstand: 2000 Vrms for 5 seconds dielectric test
-
Port-to-port isolation withstand: 2000 Vrms for 5 seconds dielectric test
-
Continuous operating isolation voltage: 60 VDC CAT I safety rating
-
ESD protection: ±15 kV human body model for all differential data lines
-
Common-mode voltage tolerance: -7 V to +12 V for RS-485 signal lines
PXI Backplane Power Specifications
-
PXI-8423/2 power draw: 800 mA typical, 1.3 A maximum @ +5 V backplane rail
-
No additional power consumption on ±12 V and +3.3 V PXI rails
-
Bus bandwidth: 132 MB/s standard PXI parallel bus throughput
-
Bus trigger support: No PXI trigger bus synchronization function
Environmental & Reliability Specifications
-
Operating temperature: 0℃ ~ +55℃ (laboratory and indoor industrial use only)
-
Storage temperature: -20℃ ~ +70℃
-
Humidity: 10%–90% non-condensing operation; 5%–95% non-condensing storage
-
Max working altitude: 2000 m, Pollution Degree 2 indoor rating
-
Compliance: CE, FCC Class A, UL 61010-1, IEC 61010-1 safety & EMC certification
Compatibility Matching List
-
Compatible PXI chassis: All legacy 3U PXI chassis including PXI-1000B, PXI-1042, PXI-1045
-
Compatible controllers: PXI-8186, all NI embedded and external PC PXI controllers
-
Supported OS: Windows XP/7/10, Phar Lap ETS real-time system
-
Official status: Fully obsolete, only aftermarket replacement inventory available
Software Compatibility
-
Drivers: NI-Serial legacy drivers, NI-VISA, NI-DAQmx all versions
-
Configuration tools: NI MAX, NI Serial Configuration Utility
-
Supported software: LabVIEW all versions, LabWindows/CVI, Python PyVISA, C# serial SDK
Pros & Limitations
-
Pros: High isolation voltage for ground loop suppression, independent per-channel FIFO for low CPU load, dual interface variants for flexible wiring, robust ESD surge protection, wide OS compatibility
-
Limitations: No built-in bus termination resistor, limited to indoor use only, obsolete hardware lifecycle, no isolated power output for external sensors








Reviews