G60-U01-AKH-F8L-H67-M8L-P6D-U6D-W6C Series Integrated Generator Protection Relay

G60-U01-AKH-F8L-H67-M8L-P6D-U6D-W6C Series Integrated Generator Protection Relay

G60: Product series, integrated protection device dedicated to medium and large synchronous generators

U01

U: CPU hardware equipped with RS485, dual fiber Ethernet ports and 1 RJ45 electrical port

01: Software license covering full basic protection functions and advanced IEC 61850 communication protocols

AKH

A: 19-inch standard vertical rack mounting

K: Enhanced high-definition color LCD operation panel

H: Wide-range redundant DC power supply of 125/250 VDC

F8L: Basic CT/VT acquisition unit with 4 phase CT channels and 4 PT voltage channels, equipped with high-precision enhanced diagnosis function

H67: Basic hard contact outputs, including 6 normally open trip contacts and 7 programmable auxiliary contacts

M8L: Extended CT acquisition module providing an additional 8 CT channels with enhanced fault diagnosis

P6D: Primary communication module with 6 communication channels, dual Ethernet plus isolated RS485, supporting IEC 61850 and PRP redundancy

U6D: Secondary redundant communication module adopting 6-channel dual Ethernet architecture for substation-wide network redundant backup

W6C: Extended control output module with 6 programmable control outputs featuring circuit supervision

Description

Full Set of Main Generator Protections

Stator differential protection (87S), 100% stator single-phase earth fault protection (optional GPM-S low-frequency injection module required), single-point / two-point rotor earth fault protection (GPM-F module);

Loss-of-excitation protection, overexcitation V/Hz protection, reverse power protection, negative sequence current protection, overcurrent / overvoltage protection, under/over frequency protection, out-of-step blocking protection, circuit breaker failure protection (50BF).

2. Communication and Network Redundancy (GE Vernova CyberSentry)

The device integrates 3 independent Ethernet switches, supporting IEC 61850 MMS/GOOSE, Modbus TCP and PRP dual-network redundancy;

It is equipped with isolated RS485 Modbus RTU and local RS232 commissioning port, and supports IEEE 1588 time synchronization as well as process bus IEC 61850-9-2LE.

3. Measurement, Fault Recording and Event Logging

Real-time electrical quantity acquisition: three-phase current / voltage, active / reactive power, power factor and harmonic components;

Event logging: 1024 fault events with high-precision time stamps;

Fault recording: up to 64 groups of fault waveform files, with synchronous recording of 16 analog channels.

4. High-reliability Operation & Maintenance Design

Full hardware channel self-diagnosis, on-line supervision of trip circuits, and hot-standby switchover of dual redundant communication networks;

CyberSentry cybersecurity protection, compliant with NERC CIP cybersecurity standards for North American power grids;

Built-in FlexLogic programmable logic for customized interlock and sequence control logic.

Application Scenarios

  1. Large thermal / hydropower / gas-fired power stations: main protection for steam, hydro and gas turbines, and complete protection for generator-transformer units
  2. New energy power stations: protection for self-provided synchronous condensers in large photovoltaic, concentrated solar power and wind power plants
  3. Industrial captive power plants: protection for generating units and waste heat units in chemical, oil & gas, metallurgical and paper-making plants
  4. Intelligent digital substations: newly-built smart power plants requiring IEC 61850, process bus and PRP dual-network redundancy
  5. Pumped storage power stations: compatible with unit protection under both power generation and pumping operating conditions without switching CT secondary circuits

Common Similar Full Models of the Same Series (Only Differences in Mounting & Configuration)

  1. G60-U01-HCH-F8L-H67-M8L-P6D-U6D-W6C: identical configuration, only HCH stands for horizontal rack mounting (the most widely used model in the market)
  2. G60-G03-AKH-F8L-H67-M8L-P6D-U6D-W6C: G03 premium software with built-in PMU synchrophasor measurement function
  3. G60-U01-AKH-F8A-H6P-M6C-P6P-U6P-WXX: simplified I/O version with fewer extended CT and output channels

VI. Classification of Generator-related Products on the UR Platform

  • G30: Simplified protection for small and medium generators with streamlined I/O and communication, applicable to units below 10 MW
  • G60: Flagship model for medium and large units, featuring multi-channel CT acquisition, dual redundant communication and complete stator / rotor earth fault protection (the model described herein)
  • T60: Transformer differential protection, exclusively for main transformers and station auxiliary transformers without dedicated generator protection logic
  • M60: Comprehensive protection for large high-voltage synchronous / asynchronous motors, not applicable to generators